Select the appliance, then the symptom closest to what the coach is doing, for the likely cause, a safe check if one exists, and whether it needs a professional.
Every symptom covered by the tool above, listed in full for reference.
Likely cause: The gap between the warm air going in and the air coming out has narrowed or disappeared. Three things typically cause that: the compressor failing, the sealed refrigerant circuit losing its charge, or the condenser coil caked with enough dust to stop shedding heat outside.
Needs a professional: A compressor or refrigerant fault is inside a sealed system and needs a technician to diagnose safely.
Likely cause: This is the telltale start capacitor failure. The capacitor supplies the extra push a compressor needs at the instant it starts, and it wears out faster than most other parts once summer heat sets in.
Needs a professional: Confirming a capacitor fault and replacing it safely needs a technician working on live electrical components.
Likely cause: The compressor may be fine while something else is starving the coach of air: a filter that has not been cleaned in a while, a dusty blower wheel, collapsed ducting, or a leaking duct joint.
Safe to check yourself: Remove and clean or replace the A/C filter behind the ceiling grille. A clogged filter is one of the most common causes of weak airflow, and clearing it costs nothing.
Needs a professional: If a clean filter does not restore airflow, the cause is inside the ducting or the blower and needs a technician to trace.
Likely cause: Restricted airflow or a low refrigerant charge has dropped the coil below freezing, and the resulting ice is now blocking what airflow was left.
Safe to check yourself: Turn the unit off completely and let the ice thaw fully before running it again. Running it while iced up only makes the blockage worse.
Needs a professional: Once it has thawed, the underlying restriction or refrigerant charge still needs a technician to find and fix.
Likely cause: Condensate normally drains off the roof through a pair of pans built into the unit. Dust and grit build up in those pans over time, and once they clog, the overflow finds the ceiling opening instead of the outside of the coach, which often gets blamed on a roof leak that is not actually there.
Needs a professional: Clearing the roof drains and ruling out a separate roof leak is roof-level work for a technician.
Likely cause: The gasket the unit sits on has aged and flattened, which lets the assembly loosen and resonate against the roof. The same loosening lets water start to get past the seal.
Needs a professional: Retorquing the assembly to the correct spec is roof-level work for a technician.
Likely cause: This points at the gas side rather than the cooling unit: soot or a spider nest choking the burner orifice, a flue packed with debris, a thermocouple too weak to hold the valve open, or a gas valve that has started sticking.
Needs a professional: Burner and gas-valve work needs a technician, since it involves the propane system directly.
Likely cause: This points at the electric heating element, the circuit feeding it, or on some models the control board that switches between modes.
Needs a professional: Electric element and control board diagnosis needs a technician with the right meter.
Likely cause: Before anything expensive is suspected, a few basics decide a lot: whether the coach is parked level, whether the outside vent is blocked, and whether the ambient temperature is extreme. If those check out, attention moves to the cooling unit or the control board.
Safe to check yourself: Confirm the coach is parked reasonably level, and check that the outside vent is not blocked by debris or a nest.
Needs a professional: If the basics check out and it still will not cool, the cooling unit or control board needs a technician to diagnose.
Likely cause: This is the sign of a leak in the sealed cooling unit, which circulates a pressurized ammonia mixture instead of using a compressor. Once that seal fails, there is no way to recharge or top it off.
Needs a professional: Stop running the refrigerator on either mode and have it inspected. It should not be run again until it has been looked at.
Likely cause: The two refrigerator types fail differently here. An absorption unit usually has an airflow problem inside the cabinet, or a temperature sensor that has slipped out of place on the cooling fin. A residential unit more often has a dead evaporator fan or a defrost cycle that is not clearing, which lets ice build up and block air movement between the compartments.
Needs a professional: Both causes require opening the cabinet to inspect, which is work for a technician.
Likely cause: Control boards wear out over time on these refrigerators, and a board on its way out can imitate almost any other problem: gas that will not light, a mode switch that will not happen, or a display that goes dark while the unit keeps running.
Needs a professional: A control board fault needs a technician to diagnose, since it can look like several other faults at once.
Likely cause: A generator that has sat unused points toward the fuel side: gasoline that has gone stale, a jet gummed shut, or a pump that has lost its prime. One that has run recently more often has an ignition problem, a fuel solenoid that is not opening, or a control board failing to energize the run circuit. A house battery too weak to spin the engine fast enough can also block a start, and that looks like a fuel issue even though it is not.
Safe to check yourself: Recall whether the generator has been run under load in the last month or two. If it has been sitting idle, stale fuel is the more likely cause.
Needs a professional: Fuel system and ignition work needs a technician to diagnose and clear safely.
Likely cause: Silence on start usually says more about the coach than about the generator. The circuit that tells it to start passes through the coach wiring and the dash switch before it ever reaches the generator's own control board, and that path needs full house battery voltage present right at the unit itself, not only back at the dash. A weak ground connection, a breaker on the generator that has tripped, or house batteries that sag the moment they carry a load will each leave it completely dead when you press start.
Safe to check yourself: Check whether the generator has its own breaker, often in its compartment or the main panel, and reset it once if it has tripped.
Needs a professional: If resetting the breaker does not fix it, the wiring, ground, or control board needs a technician to trace.
Likely cause: This pattern points to fuel starvation rather than an electrical fault: a jet blocked by varnish from old fuel, a clogged filter, a pump on its way out, or a pickup tube that has dropped below the tank's cutoff level for the generator.
Safe to check yourself: Check the fuel gauge to confirm the tank is not near empty before assuming a mechanical fault.
Needs a professional: Clearing a blocked jet or a fuel system fault needs a technician.
Likely cause: Two very different problems produce the same symptom here. Either the generator itself cannot hold its full rated output once something is drawing on it, or the appliance switching on, commonly the air conditioner's start capacitor, is pulling far more current than it should at that instant. Measuring the actual load is the only way to tell which side is really at fault.
Needs a professional: Load testing to tell the generator and the appliance apart needs a technician with the right equipment.
Likely cause: The usual causes, in order, are a dirty or blocked orifice, a weak or dead house battery (the blower and ignition run on 12-volt power, not propane), a tripped thermostat, or air that has worked its way into the LP line while the furnace sat idle.
Safe to check yourself: Confirm the house battery is not weak or dead. The blower and ignition depend on 12-volt power, not the propane supply, so a battery problem can look exactly like a gas problem.
Needs a professional: If the battery checks out, clearing the orifice and the gas line needs a technician.
Describe what the appliance is doing when you call, and it usually narrows the diagnosis before the coach arrives.